Hayward heater if code. Fixing the Hayward Heater AO Code: Now that we've identified the common causes, let's explore the fixes to resolve the AO code issue: Inspect and Clean the Air Intake: Start by turning off the heater and inspecting the air intake. Remove any debris or obstructions that may be blocking the airflow. Ensure the intake is clean and clear.

Hayward Heater LO code. Thread starter joeg679; Start date Jul 19, 2023; Jump to latest Follow Reply Forums. Equipment - Build, Use, and Repair. Pumps, Filters, and Plumbing . 1; 2; Next. 1 of 2 Go to page. Go. Next Last. J. joeg679 Member. May 28, 2017 21 NJ. Jul 19, 2023; Add bookmark #1 Hello, I was getting a Lo code on my heater and ...

Service LED ON: “IF” Code Inspect main gas supply Verify gas valve is ON Step 12B Step 12A IF “Ignition Failure”, Ensure main gas supply is in Verify that the gas valve, inside …301 Moved Permanently. nginx/1.18.0 (Ubuntu)Jun 9, 2019 ... Breif video showing the lighting procedure for Hayward H100 H150 H200 H250 H300 H350 H400 Milivolt Propane or Natural Gas Swimming Pool ...To address this issue, follow these simple steps: Turn off the power to the heater. Locate the thermostat adjustment dial, usually found near the control panel. Using a precision screwdriver, make small adjustments to the dial, clockwise to increase and counterclockwise to decrease the temperature setting.The hayward pool heater if code is an error message that appears on the control panel of your heater. This message signals that there’s a problem with the ignition system or the flame sensing rod. The if code typically appears when your pool heater tries to start but fails to ignite.

Adjust the water flow or call a professional if the pressure is too low. Clean the Filter: A dirty or clogged filter can cause Hayward Heater CE Code errors. Clean the filter thoroughly and replace it if necessary. This will improve the heater's efficiency and prevent future issues. Inspect the Ignition System: If the above steps do not ...Solution: In this case, you need to clean the dirty filter to solve it. If still it is not solved, then clean the pressure switch. 3. The Ignitor Issue. Sometimes, the Hayward pool heater ignites and runs for about 15 seconds and turns off, then it reignites and does the same thing again. Also, sometimes the flame lights, and then 1-2 seconds ...The codes indicate specific issues that need to be addressed to get the heater running again. By knowing what each code means, you can identify the problem and find a solution more quickly.400,000 BTU heating capacity. Fits directly against walls, fences, or other equipment. Competitive heaters require 6–12" wall clearance. Ultra-compact frame for easy drop-in replacement. Dual-fuel tech switches between natural gas and liquid propane. Allows for in-field conversion with a quarter-turn.So the H250 with an input of 250,000 BTU's actually puts 210,000 BTU's into the water per hour. Discounting heat loss (which there is always some) if you are using a Hayward gas heaters to heat the 18,000 gallon pool we have discussed above you will need: 22.58 therms of natural gas. 24.75 gallons of propane.2 Troubleshooting Steps. 2.1 Check Gas Pressure And Fuel Supply. 2.2 Inspect Air Supply And Venting. 2.3 Ensure Proper Water Flow. 2.4 Clean Filters And Pump. 2.5 Adjust External Bypass If Needed. 3 Tips For Diagnosing Problems. 3.1 Follow The Heater Start Sequence. 3.2 Refer To The Diagnostic Codes Manual.Use the “Mode” key to change your heater’s settings. Select the “Standby” Option and put the heater on it. Press the remote’s “Down” key and hold it and then press the Mode key and hold it simultaneously. For 3 seconds, hold down both the “Down” and “Mode” keys as long as the “bo” code doesn’t remove from your ...Hayward Heat Pro W3HP21104TC 110,000 BTU Lo Ambient pool heater pump has continuous temperature display, self-diagnostic codes, UV-resistant cabinet. Call Us Nationwide: 1-800-741-9956. ... Hayward W3HP21104TC Pool Heat Pump - Lo Ambient - 110,000 BTU Features & Benefits:

Stumbling upon a 'LO' code on your Hayward heater can be quite the head-scratcher. Don't worry, you're about to unravel the mystery behind this cryptic message. This code typically indicates a water temperature sensor error, but it can also be a sign of other underlying issues with your pool heater. In this article, you'll learn the steps to diagnose and fix the problem, ensuring your pool remainsThis pool heater transfers 250,000 BTU of heat, and is fitting for swimming pools with a surface area of up to 750 square foot. This pool heater can raise the temperature of 1,000 gallon pools to 15 degrees Fahrenheit in just 36 minutes. 7. Hayward Universal H-Series Pool and Spa Heater – Model#H350FDN.I have Hayward H150FDN Universal H-Series, Low NOx, 150,000 BTU, Natural Gas, Pool and Spa Heater and I am getting a LO code with is a flow problem. I have my intermatic timer set for 755am to turn on and give my equipment power, then at 8am the Hayward pump turn on. Can the heater be on...Hayward W3H300FDN Universal H-Series Low NOx 300,000 BTU Natural Gas Residential Pool and Spa Heater with Bundle* Warranty Better Buy Pool Supply will provide you with the Full 2 Year Manufacturer's Warranty plus 1 Year Installation Warranty upon installation by our professionals. From the Manufacturer The Universal H-Series is an energy efficient, high performance, installation […]Heater Hayward ED2 Fault Code Thumbnails (18 pages) Heater Hayward C-SPA-XI 5.5 Installation And Operation Manual. Pool and spa/hot tub heaters (24 pages) Summary of Contents for Hayward H150FDN.Sep 10, 2023 · Clean the hayward heater regularly to prevent any debris buildup, which can trigger the if code. Remove leaves, sticks, and other objects from the heater. Check the air filter and clean or replace it as needed. A dirty filter restricts airflow and can cause the heater to overheat, resulting in the if code.

Fishingwithluiza.

Some of the most reviewed products in HAYWARD Pool Heaters are the HAYWARD Universal H-Series Propane Gas 150,000 BTU Low NOx Pool Heater with 5 reviews, and the HAYWARD Universal H-Series Natural Gas 400,000 BTU Low NOx Pool Heater with 4 reviews. Related Searches. hayward pool heater.The Hayward H-Series' Finn Plate cupro-nickel heat exchanger has special V-groove design for faster heating and longer life. Hayward Universal H-Series, Low NOx, 250,000 BTU, Natural Gas, Pool and Spa Heater delivers energy efficient heating to your pool's water that you can trust. Hayward Universal H-Series - Versatility & PowerService LED ON: “IF” Code Inspect main gas supply Verify gas valve is ON Step 12B Step 12A IF “Ignition Failure”, Ensure main gas supply is in Verify that the gas valve, inside …Feb 4, 2017 ... Hayward H400 Pool Heater IF Error Code ignition Failure (IDXLFLS1930) Flame Sensor Replacement. Eloy Castaneda Jr•13K views · 6:41 · Go to ...

View online or download Hayward H150FDN Owner's Manual, Troubleshooting Manual ... Brands; Hayward Manuals; Heater; H150FDN; Hayward H150FDN Manuals. Manuals and User Guides for Hayward H150FDN. We have 3 Hayward H150FDN manuals available for free PDF download: Troubleshooting ... Diagnostic Codes and Part Numbers. 19. …Learn How Solar Pool Heaters Work; Learn About Hayward. At Hayward, we're more than just equipment. Learn more. Hayward Insights. Hayward Insights. Hayward Insights provides expert advice, tips, and industry updates to help pool owners and enthusiasts with their swimming pool experience. Gain insight. Support.When your Hayward pool heater flashes the ‘bo code’, it’s signaling that there’s an issue with the bypass operation. Here’s a strategic approach to get your heater back to optimal functionality. Reset the Heater: Turn off the heater and the circuit breaker for 30 seconds. Power up the system again to see if the ‘bo code’ persists.Heater will not power up Pages 14-22 Open FC1 and/or FC2 Fuse Pages 23-24 Open FC3 and/or F1 Fuse Pages 25-28 Open FC4 Fuse Pages 29-31 Diagnostic Codes Page 32 BD Code Pages 33-34 EE and CE Codes Page 35 IO and SB Codes Page 36 SF and HS Codes Page 37 ... Hayward Part # FDXLFSKF30 (Qty. 10) Step 1:Hayward Serial Numbers and Date Codes 1. Heat Pumps, Heaters, Filters, Pumps February 2004 - February 2010 ... Hayward 2015 ID Tag . 3A0112 = Standard Warranty Term 3A0112 = Product Family 3A0112 = Year of Manufacture 3A0112 = Month of Manufacture 123456 = Manufacturing ID 2. Chemical Automation, Controls, Lighting (Prior to 8-5-2011)How To Read Serial Number & Date Codes Heat Pumps, Heaters*, Filters, Pumps 2005 & Forward (21) 120-402-000002006 Pictured above is the new Hayward ID Tag that will replace our current serial number system. To the left is an explanation of The 6th -8th number will be the year & month. Example: 402=2004, Feb 405 = 2004, May 501 = 2005, Jan 502 ...Hello, I have a new inground pool and all brand new equipment. My Hayward 400K heater has worked intermittently for 1.5 days. It brought pool up to temp, but now, keeps getting IF code and wont restar … read more400,000 BTU heating capacity. Fits directly against walls, fences, or other equipment. Competitive heaters require 6–12" wall clearance. Ultra-compact frame for easy drop-in replacement. Dual-fuel tech switches between natural gas and liquid propane. Allows for in-field conversion with a quarter-turn.The 5th and 6th digits of the serial number of a Hayward heat pump pool heater are the year of manufacture, and the next two are the month. So the example shown below was produced in August, 2017. This serial number system has been in effect since May, 2010. For models manufactured from 2005 to mid-2010, a typical serial number looked like this ...GAS HEATERS: Universal H-series ASME Heater: 3 Years: CHLORINE GENERATOR & UVO3 SYSTEMS: Saline C ® 6.0 & 11.0 Salt Chlorine Generators: 2 Years* None: 2 Years* None: 2 Years** 2 Years* *Salt cells carry an 18 month parts warranty. * No field labor, factory repair labor only. **Salt cells carry a 1 year full warranty & a prorated warranty for ...Turns on then heater shuts off trying 2 fix 🙏🏽

The tech did the install and ran the heater only for a few minutes to check for ignition and stuff. He had done some other plumbing work so he didn't want to run in too long, or the pool pump either, so that the PVC glue really had some time to cure. The heater is a 400,000 BTU Hayward Universal HC Series Model HDF400 Pool Heater.

3. Optional Additional Controls, Ability to add additional multi module relays or single smart or standard relays to Hayward Omni Controls (see compatibility chart)., 4. Optional Remote Controls, Remotes include a wired or wireless with touch screens display. Website and apps are available for use on a smartphone or tablet., 5.My hayward H250FDN pool heater runs for about a minute then the code comes up LO. I had a technician out and he checked all the safetys and they were good. I had patched a hole in the heat exchanger j …The IF code on your Hayward pool heater points to an ignition problem, usually occurring when the heater fails to ignite or the ignition process is interrupted. Advertisment. Read more The Ultimate Guide to Stronger Floors. However, This could result from gas supply issues, ignition control module problems, or defective igniters. Timely ...Hayward H400FD Manuals. Manuals and User Guides for Hayward H400FD. We have 13 Hayward H400FD manuals available for free PDF download: Service & Installation Manual, Manuel D'entretien Et D'installation, Owner's Manual, Quick Manual, Quick Reference Manual.9 comments. Best. Add a Comment. ttsignal24 • 1 yr. ago. Remove the Orifice units and see if there is debris inside. Spider webs etc. Tray again. If no go, then you will need to replace main board. It's unlikely that the igniter is bad already, but possible. 3. View and Download Hayward H250FDN service & installation manual online. POOL AND SPA/HOT TUB HEATERS. H250FDN heater pdf manual download. Also for: H250fdp, H350fdn, H350fdp, H400fdn, H400fdp. The Lo on a Hayward heater means “low.” When the Lo setting is selected, the heater runs at a lower speed, which can help conserve energy. In some cases, the Lo setting may indicate a malfunction or another issue with the heater. If you notice your Hayward heater displaying an LO code, it is important to check the manual or contact …

Rally's byram ms.

Miami dadeclerk.com pay parking ticket.

Check the Gas Valve. Start by ensuring that the gas valve is open and allowing the flow of gas to the pool heater. If the gas valve is closed or partially closed, the heater won’t receive the necessary fuel to ignite. Make sure the valve is fully open and functioning correctly. We have 4 Hayward H400FDN manuals available for free PDF download: Troubleshooting Manual, Service & Installation Manual, Owner's Manual Hayward H400FDN Service & Installation Manual (64 pages) POOL AND SPA/HOT TUB HEATERS The Hayward Universal H-Series gas heater is one of the most energy-efficient Pool and Spa heating solutions on the market! Its ground-breaking hydraulic design reduces pump circulation run time, giving you an energy savings of up to 18%! This unit is perfect for the environmentally conscious Pool and Spa owner thanks to its Low NOx capabilities.When it comes to hayward heaters, there are some common bd codes that you might encounter. Bd1 indicates ignition failure, which can often be resolved by cleaning the ignition assembly. Bd2 suggests water temperature sensor failure, which can occur due to a faulty sensor or connection issue. If you see bd3, it indicates high limit switch open ...Oct 18, 2020 ... was getting CE code, aka Communication Error. Replaced main board, display board, and display panel.Heater Hayward ED2 Fault Code Thumbnails (18 pages) Heater Hayward C-SPA-XI 5.5 Installation And Operation Manual. Pool and spa/hot tub heaters (24 pages) Summary of Contents for Hayward H150FDN.By carefully following these steps and additional advice, you should be able to effectively diagnose and resolve the AO code issue on your Hayward heater. Have a question about pool heaters? Airlucent owner Tim David would like to answer your question in an upcoming article, call (256) 399-9708 or contact David via the contact page .My pool heater quit working. It would try to start, but then fail. The error code "IF" was displayed. It was an "Ignition Failure Lockout". I looked at a... Here you’ll gain easy access to information regarding your favorite Hayward products. Whether you are looking for a Quick Reference Guide, troubleshooting steps, or simply wish to view one of our product support videos, you have come to the right place. Mar 24, 2023 · Turn off your heater, wait a few minutes, then power it back on. If the AO Code persists, move on to the next step. Check the wiring: Inspect the wiring between the blower vacuum switch and the control board. Look for loose connections, damaged wires, or other signs of wear and tear. If you spot any issues, call a professional for assistance. ….

A protective winter cover is also offered by your retailer. 22 OWNER’S MANUAL Hayward® Heat Pump Pool Heater Limited Warranty The Hayward heat pump pool heater is warranted by the manufacturer to be free of defects in materials and workmanship for a period of two (2) years for parts and (1) one year for labor. What do Flowsensor Alarms Mean? The Flowsensor detects water flow from the filter pump in a Body Of Water. It is unsafe to run water treatment features, such as heating, Chlorination, or pH adjustments while there is no water flow.Description: This recall involves the Hayward UHXNEGVT15001 Negative Pressure 6-inch Vent Kit for pool heaters. The vent kit is used exclusively on the Hayward H500FD Gas Heaters. The kit includes the following: one vent pipe adapter for negative pressure galvanized vent pipe, one flue cover plate with hole for vent, #10 sheet metal screws ...Heater Hayward ED2 Fault Code Thumbnails (18 pages) Heater Hayward C-SPA-XI 5.5 Installation And Operation Manual. Pool and spa/hot tub heaters (24 pages) Summary of Contents for Hayward H150FDN.Our network of certified personnel can help you build your pool, recommend a product, repair a faulty product, and test your water. Find a professional near you. Hayward offers environmentally responsible, cutting-edge pool and spa equipment for residential and commercial, in-ground and above-ground pools.It is glowing and I get ignition (the whoosh) for about 3-5 seconds and then it goes out. I have not cleared out the orfices yet, but I assumed they were fine due to it working just a couple weeks ago.Understanding the Hayward Heater BD Code. When your Hayward pool heater displays the BD code, it’s essentially indicating a problem that needs attention. This code is a diagnostic tool designed to help you identify the issue so you can take appropriate action. While it may seem intimidating, diagnosing and fixing the problem can often be …Apr 4, 2020. #7. You can check the ignitor with a meter by measuring the ohms at the 2 leads coming from the ignitor. An older silicon carbide ignitor ( shiny crystalline and fragile ) will normally ohm out at 45-150 ohms. A newer silicon nitride ignitor ( Looks like a smooth dull black matchstick ) will normally ohm out at about 11-17 ohms.Hayward's Universal H-Series 400,000 BTU natural gas pool and spa heaters provide reliable, long-lasting comfort for pools and spas with surface areas up to 1,200 feet. Manufactured with a durable copper-nickel heat exchanger that provides superior protection against corrosion and premature failure due to water chemistry imbalances, ensuring ... Hayward heater if code, With variable speed pumps, ensure you have the RPM of the filter pump set at 2200 RPM. Check and clean the heaters' heat exchanger. Remove and inspect the High limit sensors, and there are two located in the header of the heater. If there are any signs of corrosion or calcium buildup, replace them., The Hayward Universal H-Series gas heater is the "universal" energy efficient remedy for any new or existing pool or spa. An industry leading hydraulic design reduces circulation pump run time to provide energy savings of up to 18% when compared to less efficient competitors., hayward pool heater HD1001D1 will heat for 5 seconds then stops. I have jumped aroune the two sensors on the water line and still operates the same. The thermostat and igniter have been replaced and s …, The electric heaters fit into compact spaces — even under spa skirts or steps. Like all Hayward heaters, they are easy to install and service. • 304 stainless steel tank, • 304 stainless steel threaded head, safety sensor electric heating element, • Service-ease design gives simple access to internal controls, • Heater on indicator light,, Hayward H250FDP pool heater showed SF code. Replaced the thermistor and restarted the power. Display still shows SF code and sevice light on. Cycled the mode button and the blower comes on, but no ign … read more, Audio turned out weird, so you may have to turn the volume up!How to diagnose and repair your Hayward H Series (H250) Gas pool heater. Audio turned out weird, so you may have to turn the volume up ..., The Hayward Universal H-Series gas heater is the "universal" energy efficient remedy for any new or existing pool or spa. An industry leading hydraulic design reduces circulation pump run time to provide energy savings of up to 18% when compared to less efficient competitors., Enter a postal code to find the nearest Hayward authorized pool professional. Postal Code: How far from the above postal code do you want to search? Enter the miles in the box below. Minimum of 10 miles, maximum of 100. Radius: miles. Pool Type: ... Heaters (not including Heat Pumps) Heat Pumps. Lighting. Pumps. Variable Speed Pumps ..., Learn How Solar Pool Heaters Work; Learn About Hayward. At Hayward, we're more than just equipment. Learn more. Hayward Insights. Hayward Insights. Hayward Insights provides expert advice, tips, and industry updates to help pool owners and enthusiasts with their swimming pool experience. Gain insight. Support., Step 1: Shut the power off and then take out all the screws from the display board. After taking off the whole board you’ll see that there is a lower panel on the other side. Take off the two screws and undo them. Step 2: You’ll see a ribbon cable. Take that off and then unscrew the underneath panel., 4. 5. Explore Hayward's pool parts and accessories for maintenance and upgrades. Find high-quality replacements, equipment, and supplies to enhance your pool experience., Selecting "0" will allow the keypad to remain unlocked. Selecting "1" will enable the User Lock Code option. Then, to enter a lock code number, press the [POOL/SPA] key once to display [ELC] (Enter Lock Code). With [ELC] displayed, use the Up or Down arrow keys to select a lock code. The code can be any number from "00" to "99"., Step 1. To perform a range test unplug the ACHN and hold down the "Teach" button. While holding down the button plug in the power cable. Step 2. Keep holding down the teach button until the LEDs flash in unison; once flashing let go of the teach button and watch the LEDs. Step 3., Hayward H200FDN pool heater stopped working during the couple of days of heavy rain late last week. There is power to it, can hear a buzzing inside. Changed the low voltage fuse, fan came on briefly., For hayward pool heater if code repair, check the pressure switch and ensure proper pressure is being reached. Hayward pool heaters display an "if" code when the pressure switch is not closed. This is caused by insufficient water flow, closed valves, air in the system, or a clogged filter. It is important to identify and fix the issue ..., Hayward Heater LO Code. December 14, 2022 by Raul Ohara. Updated on December 14, 2022. Malfunctioning heaters can be a real headache and Hayward's LO code is the alarm bell to start diagnosing - it could result from faulty pressure or temperature switches, leaving you with a multitude of potential culprits. Take your time identifying which ..., By carefully following these steps and additional advice, you should be able to effectively diagnose and resolve the AO code issue on your Hayward heater. Have a question about pool heaters? Airlucent owner Tim David would like to answer your question in an upcoming article, call (256) 399-9708 or contact David via the contact page ., The Hayward H-Series' Finn Plate cupro-nickel heat exchanger has special V-groove design for faster heating and longer life. Hayward Universal H-Series, Low NOx, 150,000 BTU, Natural Gas, Pool and Spa Heater delivers energy efficient heating to your pool's water that you can trust. Hayward Universal H-Series - Versatility & Power, 3. Optional Additional Controls, Ability to add additional multi module relays or single smart or standard relays to Hayward Omni Controls (see compatibility chart)., 4. Optional Remote Controls, Remotes include a wired or wireless with touch screens display. Website and apps are available for use on a smartphone or tablet., 5., Hayward Heater LO Code. December 14, 2022 by Raul Ohara. Updated on December 14, 2022. Malfunctioning heaters can be a real headache and Hayward's LO code is the alarm bell to start diagnosing - it could result from faulty pressure or temperature switches, leaving you with a multitude of potential culprits. Take your time identifying which ..., Ensure the proper installation of the main circuit board within the heater. Check the short ground and high voltage issue and take steps to prevent it. 5. Circuit Board's Faulty Fuse. Another factor responsible for displaying the Hayward pool heater ce code is the faulty or blown fuse in the heater's circuit board., Discover the power of heat pumps for efficient pool heating with Hayward's comprehensive knowledge base. Learn about the latest advancements in heat pump technology, explore our range of energy-efficient models. ... With a heat pump, heat is transferred from the surrounding air to the pool water. Gas heaters can operate in almost any climate ..., FAQ: What are the Hayward pool heater lockout settings? The maximum lockout settings for the pool mode are 90ºF and 104ºF for the Spa mode by default., Hayward Insights provides expert advice, tips, and industry updates to help pool owners and enthusiasts with their swimming pool experience. Gain insight. Support. ... Rear Clearance - Heaters: 6 in: Refrigerant: No: Series Heaters: Universal HSeries: Shipping Dimensions: 30.6 " x 32.8 " x 33.3 "Shipping Height: 30.6 in: Shipping Length: 33.3 ..., Hayward's Universal H-Series 400,000 BTU natural gas pool and spa heaters provide reliable, long-lasting comfort for pools and spas with surface areas up to 1,200 feet. Manufactured with a durable copper-nickel heat exchanger that provides superior protection against corrosion and premature failure due to water chemistry imbalances, ensuring ..., View online or download Hayward H400FDN Owner's Manual, Troubleshooting Manual ... Brands; Hayward Manuals; Heater; H400FDN; Hayward H400FDN Manuals. Manuals and User Guides for Hayward H400FDN. We have 4 Hayward H400FDN manuals available for free PDF download: Troubleshooting ... Diagnostic Codes and Part Numbers. 19. Troubleshooting Guide. 20 ..., A protective winter cover is also offered by your retailer. 22 OWNER'S MANUAL Hayward® Heat Pump Pool Heater Limited Warranty The Hayward heat pump pool heater is warranted by the manufacturer to be free of defects in materials and workmanship for a period of two (2) years for parts and (1) one year for labor., Feb 4, 2017 ... Hayward H400 Pool Heater IF Error Code ignition Failure (IDXLFLS1930) Flame Sensor Replacement. Eloy Castaneda Jr•13K views · 6:41 · Go to ..., Use the “Mode” key to change your heater’s settings. Select the “Standby” Option and put the heater on it. Press the remote’s “Down” key and hold it and then press the Mode key and hold it simultaneously. For 3 seconds, hold down both the “Down” and “Mode” keys as long as the “bo” code doesn’t remove from your ..., Minimum inlet gas pressure. 10.0”. Using a Manometer, take a measurement at the inlet port on the gas valve for both Static Pressure (heater o ) & Load Pressure (heater red); readings should be within the values on the heater data plate. Then measure the Manifold Pressure from the outlet port on the gas valve. Inlet Port., Hayward Pool Heaters are perfect for any new pool construction, diy pool build or a simple renovation. ... Hayward W3H135FDN H-Series 135K BTU Natural Gas Above Ground Pool and Spa Heater $ 1,999.00 Add to cart; Hayward HeatPro 50K BTU Horizontal Fan Heat Pump $ 2,359.00 Add to cart; Out of stock. ... Use Code: MAYTRONICS20., The Hayward Pool Heater IF code indicates an ignition failure. This means that the heater was unable to ignite the gas properly, preventing it from operating as intended. IF Code Quick Troubleshooting Steps. Refers to an ignition failure. Check gas supply and ensure valves are open., On Sale. $176.80. Was: $199.99. Quantity: Select all. Add selected to cart. Description. Hayward Display Board Only is a replacement part of induced draft heater.