4 ton 410a piston size

no warranty claim will be honored for mix-matched systems that fail to adhere to the specified piston size. warning gsx140301a* asx140301(b,c)* ssx140301(a,b)* awuf 31 & 32 all other ahri matches 0.061 0.065 b1789861 b1789865 tx3n4 tx3n4 2,3 1,3 anx140301a* awuf 31 & 32 all other ahri matches 0.061 0.065 b1789861

4 ton 410a piston size. 3/4" FEMALE NPT PRIMARY & SECONDARY DRAIN CONNECTIONS (IMPORTANT: HAND TIGHTEN) SUCTION CONNECTION LIQUID CONNECTION CAPF3636C6 PISTON SECTION XSEC0002-XSEC0002 Specifications Model Cabinet Dimensions Nominal Tons Connection Piston Size* (in.) Ship Weight W D H Liquid Suction (lbs) CAPF3137B6 17½" 21" 30" 2½-3 ⅜" ¾" .071 53

piston kit chart 4 ppkcg-4001j february 2015 (*) signifies unit revision. (1) correct piston is supplied with the outdoor unit. (2) correct piston is supplied in the highest sales volume tested combination indoor unit. for all other indoor combinations, piston must be purchased from distributor. (3) txv must be purchased separately.

piston kit chart 4 ppkcg-4001j february 2015 (*) signifies unit revision. (1) correct piston is supplied with the outdoor unit. (2) correct piston is supplied in the highest sales volume tested combination indoor unit. for all other indoor combinations, piston must be purchased from distributor. (3) txv must be purchased separately.Condensing Unit Air Handler / A-Coil Piston Size / TXV Valve Model SEER "Preinstalled Piston" Attached Piston If Preinstalled Piston Replace Required AC M4AC4018C1000AA M4CXC028BA1CAAA 051 / (MAYTXVACHP1830AA) 14 064 068, 058, 057, 050, 069, 051 YES M4CXC030BB1CAAA 051 / (MAYTXVACHP1830AA) 14 063 068, 058, 057, 064, 050,NO WARRANTY CLAIM WILL BE HONORED FOR MIX-MATCHED SYSTEMS THAT FAIL TO ADHERE TO THE SPECIFIED PISTON SIZE. WARNING Indoor Unit Indoor Piston …3/4" FEMALE NPT PRIMARY & SECONDARY DRAIN CONNECTIONS (IMPORTANT: HAND TIGHTEN) SUCTION CONNECTION LIQUID CONNECTION CAPF3636C6 PISTON SECTION XSEC0002-XSEC0002 Specifications Model Cabinet Dimensions Nominal Tons Connection Piston Size* (in.) Ship Weight W D H Liquid Suction (lbs) CAPF3137B6 17½" 21" 30" 2½-3 ⅜" ¾" .071 53If you’re new to carpentry and woodworking you may be surprised to learn that lumber today is actually smaller in both width and thickness than its listed size. Expert Advice On Im...piston kit chart (*) signifies unit revision. (1) correct piston is supplied with the outdoor unit. (2) correct piston is supplied in the highest sales volume tested conmination indoor unit. all other indoor combinations, piston must be purchased from distruibutor. (3) txv must be purchased separately. pkcg-4001zb february 2020 ^ ] Ì e }

ADP 100000039 - Piston .67, 2 1/2 Ton R22, 3 Ton R410APiston Size 67. Can be used on 2 1/2 Ton R22 Coil or 3 Ton R410a Coil. The store will not work correctly in the case when cookies are disabled. Due to scheduled maintenance, some website features will be unavailable on Saturday 10/29. ...Rheem 4 ton 16 seer split system w/410a R22/410 system Refrigeration dupont handbook piping I have a rheem 80 plus model number rgdc-10ncbjr. the exhaust blower Goodman piston size chart r22Checking the charge on a heat pump in the winter R410a charging chartRheem hvac ac b702 9ce1 4acf.Goodman 2.5 to 3 Ton TXV Kit - R-410A; SKU: TX3N4: Weight (in lbs) 2.500000: Brand/Manufacturer: Goodman: Refrigerant: R410A: Safety Information: PROPOSITION 65 WARNING . Reviews 1. Write Your Own Review. You're reviewing: Goodman 2.5 to 3 Ton TXV Kit - R-410A Your Rating. Price. 1 star 2 stars 3 stars 4 stars 5 stars ...What piston size for Goodman SSX140421A/ARUF 374316- 3.5 ton 14 seer R410a? - Answered by a verified HVAC Technician. We use cookies to give you the best possible experience on our website. ... Existing equipment is a 4 ton 10 seer r-22. If a 3.5 ton 14 seer 410a is installed in its place, ...100000042 ADP Piston - size 76 R410A (4 Ton) Abrpn: 100000042. Your No. This is non stock item. More Information. SKU. 104214. Default UOM.

Garage doors can make or break your home and equally important is the size. This contributes to functionality and overall style. Below we’ve rounded up a Expert Advice On Improving...Description Piston Size. Part Number. Qty; For Coils Size (MBTUH) 41 176799941. 10. 12; ... standard R-22 and R-410A pistons listed above (100 pistons total) in a ...Piston size-non tXV use Tonnage R22 (F) R410A (G) Orifice Sz PART # Orifice Sz PART # 1T 0.041 3962 N/A N/A 1.5T 0.055 3999 0.049 4006 2T 0.059 4000 0.055 3999 2.5T … 2 Ton Orifice Kit for R-410A, 14 SEER Air Conditioner. Goodman B1789857. 6 $ 9 99 $13.66. Out Of Stock. Compare. Piston Kit - 0.078. Goodman B1789878. New Item! $ 9 ...

Adventist health howard memorial.

If you've considered backing up your entire DVD collection, or duplicating your hard-drives-full of RAW photos in case of electromagnetic terrorism, then you've looked at your back...Existing equipment is a 4 ton 10 seer r-22. If a 3.5 ton 14 seer 410a is installed in its place, does the seer make up for the 1/2 ton? … read more.If you've considered backing up your entire DVD collection, or duplicating your hard-drives-full of RAW photos in case of electromagnetic terrorism, then you've looked at your back...Piston size-non tXV use Tonnage R22 (F) R410A (G) Orifice Sz PART # Orifice Sz PART # 1T 0.041 3962 N/A N/A 1.5T 0.055 3999 0.049 4006 2T 0.059 4000 0.055 3999 2.5T …Be the first to ask a question about this product! Product Features. Product DetailsCorrection on reply # 15 - GSZ140481A piston size should be .078 not .080 Lessons learned the hard way.--Don't let brain think 13 SEER - R22 when working on 14 SEER -R410A -- Make sure new condenser has piston with it. Put piston chart in vehicle-carry it with me. rollandsaxton liked this post.

Oxbox J4MXCC009AC6HCA - 4 - 5 Ton Multi-Position Cased Evaporator Coil (21" W x 21" D x 30" H)- Product Features: Oxbox indoor coils can be adapted to 13, 14 and 16 SEER models 1.5 – 5 ton models available All-aluminum coil design Multi-positional installation — upflow, downflow, horizontal left, horizontal right Foil-faced thermal ...3. Remove the piston from the mechanical fitting in liquid line. Remove and discard the O-ring. NOTE: Remove the piston. 4. Install new O-ring on fitting. O-ring is supplied in kit. 5. Using a back-up wrench, reattach the fittings. Tighten until bodies “bottom” or a definite resistance is felt. The valve will only fit in one direction of flow.Sep 12, 2013 ... Can you install a 410a condensing unit on a r22 system. Fast Affordable Air•150K views · 4:27. Go to channel · HVAC Service Call | Clogged ...MFH COIL AC PISTON .093 4-5T STD-HI EFF 13-15 SEER. ... PISTON .093 4-5T. -Product Detail. CMH48/60PM2M. MFH ... 410A Nom. Capacity (Tons) 4-5 Fits Furnace Width ( ...Be the first to ask a question about this product! Product Features. Product DetailsLiquid Line Size: 3/8 in Metering Device: Piston Motor Rating: 1/3 hp Motor Type: PSC Nominal Capacity: 3.5 ton Power Source: 208/230/1 Refrigerant Type: R-410A Series: B6BMM0 Suction Line Size: 7/8 in Supply Air Opening: 12-7/8 x 18-1/4 in. Similar Products Found in: > ELECTRIC FULL-SIZE SYSTEM ADP - 176799976 - 4 Ton Piston Size 76 R-22/R-410A. Item: ADP176799976 . MFG: 176799976 Insulated air handler blower & coil compartments. Condenser pre-charged with R410A refrigerant. Suitable for use in manufactured & mobile homes. Integrated Horizontal Drain pans and metal Vertical Drain. Specifications. Condenser Dimensions: H38 1/5" x W30 1/5" x D30 1/5". Air Handler Dimensions: H54 1/2" x W22" x D24".According to my chart the GSZ14048 takes a .80 piston. Also Goodman does not ship the piston with the 14 SEER condensers. I guess they wanted to save a buck per unit since most have the option for TXV too. You definitely can not count on the correct piston being shipped in the AH or coil either.4 Ton*. 22.5". 3 Ton. 16.5". PROTECTION. ADP is the ... 1: Piston (R-410A). 2: Piston (R-22). 6: Non-bleed A/C ... Piston Size [3]. AP: TXV access port [4]. MBTUH R ...

Product Overview. C35 Indoor Coil C35-48B-2F. Up-flow, full-cased models. 1.5- to 5-ton capacities. Large surface area for high-efficiency operation. Lighter, rifled aluminum tubing, hairpins, distributor and header tubes for improved durability in certain environments. Non-corrosive, UV-resistant polymer drain pan with dual connections.

This manual is also suitable for: View and Download Goodman GPH 14 SEER R-410A technical manual online. GPH 14 SEER R-410A Package Heat Pump Units. GPH 14 SEER R-410A heat pump pdf manual download. Also for: Gph1424h41ab, Gph1430h41ab, Gph1436h41ab, Gph1442h41ab, Gph1448h41ab, Gph1460h41ab.Buy Goodman B1789857 2 Ton Orifice Kit for R-410A, 14 SEER Air Conditioner. Goodman technical support information, product brochures and more. ... This orifice (also referred to as a piston) is installed in an evaporator coil when the coil has a different tonnage rating than the condenser tonnage rating. Installation takes about 5 minutes, …Effective 4/1/10. Subject to change without notice. R22 (F) R410A (G) ... 3.5T 0.080 3990 0.074 4001 4T 0.084 3991 0.080 3990 5T 0.092 3998 0.089 3960 Table 1: Piston Size- Non TXV use NOTE TO THE INSTALLER: These instructions are for the use of qualified individuals trained and experienced ... for R-410a and green for R-22) to assist with ...None of the systems I retrofitted employed pistons after converting to 410A. The largest system I did was 5 ton. Some utilized pistons with 22 but I put in TXVs for 410A. Some others utilized TXVs with 22 and I just changed the TXV. These were all split system but I have seen some 7.5 ton 410A RTUs with pistons. New build though, not …Factory supplied charge R-410A; Glossy corrosion resistant finish; High pressure switch; ... Silver Series 3 Ton, 14 SEER, R410A, Air Conditioner Unit, 208-230/1/60: Item Number: 4A7A4036L1000A: ... Drain Connection Size: 3/4" Suction Line Fitting: Sweat or Braze: Suction Line Size (OD) 3/4" Liquid Line Fitting:Buy Goodman B1789857 2 Ton Orifice Kit for R-410A, 14 SEER Air Conditioner. Goodman technical support information, product brochures and more. ... This orifice (also referred to as a piston) is installed in an evaporator coil when the coil has a different tonnage rating than the condenser tonnage rating. Installation takes about 5 minutes, … (2) correct piston already provided on indoor coil 61000 .090 (2) (3) purchase piston kit from distributor 62000 .090 (2) (4) b17898-65 piston provided on indoor coil ae(r)60 .090 (2) (5) correct piston already provided on outdoor unit (at the liquid service valve) piston kit chart note: most units are shown as the root unit.

Red tide map naples.

Mike simpson knx.

Piston fancoils are no longer offered in the 5 ton size; therefore none of the 5 ton outdoor models show an indoor piston size. 13 SEER “E” series split Heat Pumps: N4H3**(A,G)KE C4H3**GKE H4H3**GKE T4H3**GKE All models have the required R-410A indoor piston size printed on the outdoor unit rating plate. All models include one R-410A indoor ...The Goodman CAPF3636B6 evaporator coil is rated for a 3 ton output. In many system configurations, this coil may be larger in tonnage than its paired condenser. This is intentional, to maintain the overall efficiency of the entire system. Please note that in order for this coil to function, a furnace or blower and a condenser is required, all ...Capillary Tube Length (in.) 17.810 (1). Inside Diameter (in.) .095 (1). Number of Capillary Tubes. 6 (4); 3 (2); 2 (1). Orifice Diameter (in.). Lennox 11W11 - R410A Piston 5 Ton. The 11W11 R410A Piston is a critical component designed specifically for use in air conditioning systems utilizing R410A refrigerant. With a capacity to handle 5 tons of cooling, this piston plays a crucial role in regulating the flow of refrigerant within the system to ensure efficient and optimal performance. Shopping locally can help small businesses and local economies thrive. Detroit Pistons, Corporate Sponsors Support Small Businesses Through Grants and Promotions. Shopping locally ...Liquid Line Size: 3/8 in Metering Device: Piston Motor Rating: 1/3 hp Motor Type: PSC Nominal Capacity: 3.5 ton Power Source: 208/230/1 Refrigerant Type: R-410A Series: B6BMM0 Suction Line Size: 7/8 in Supply Air Opening: 12-7/8 x 18-1/4 in. Similar Products Found in: > ELECTRIC FULL-SIZE SYSTEMIf it does not match, replace indoor piston with correct piston size. (Indoor pistons are shipped with some outdoor models in the accessory bag and are only qualified for Piston fan coils.) Example fan coils with piston: FEM4P, FSM4P, FSU4P (12 thru 4 ton). See Figure 4. When changing indoor piston, use a back−up wrench.Product Overview. C35 Indoor Coil C35-48C-2F. Up-flow, full-cased models. 1.5- to 5-ton capacities. Large surface area for high-efficiency operation. Lighter, rifled aluminum tubing, hairpins, distributor and header tubes for improved durability in certain environments. Non-corrosive, UV-resistant polymer drain pan with dual connections. ….

A tech could do a poor job of installing the R22 condenser and the unit would last for 10 years or more. With r410a units, the installers must have there process dialed in tight. No more sweep charging or fast flush. Each system must be vacuumed down to …Goodman-Amana B1789859 - Restrictor Orifice, B1789859- 13 SEER fixed orifice piston kit. Orifice opening of .059 for 2.0 ton R-22 and 2.5 ton R-410A units (GSX130301AB) Free shipping on orders over $99*Piston size needed for system combination may not be pre-installed. See Table 1 for pre-installed size. **Necessary piston size varies for this tonnage. See Table 3. Table 3. R410a piston sizes for 2.5T outdoor capacity system. Piston Unit Model* Coil Model Size (R410a) 4MXCA001AC6HCA 0.052 factory installed 4MXCB002AC6HCA 0.052 factory installedTelegram announced today that will it hold an auction for usernames through a marketplace on the TON blockchain. Telegram announced today that will it hold an auction for usernames... 4 To 5 Ton TXV Kit - R-410A Refrigerant. ( 5 Reviews) Model: Blueridge BGH4TXV03. $ 109.99. Or as low as. Buy in monthly payments with Affirm on orders over $50. Learn more. You save: 30%. Compare to: $157.92. Piston size chart 410a Piston metering device orifice opening: 0.049 for r-410a 1.5 ton Hvac piston size chart. Goodman Piston Chart | Hot Sex Picture ... Hvac piston size chartArmstrong em1p48bg 4 ton multiposition cased coil piston r22 or 410a Carrier piston size chart r410aPiston 1.5t r22 2t r410a (#53) adp.Rheem 4 ton 16 seer split system w/410a R22/410 system Refrigeration dupont handbook piping I have a rheem 80 plus model number rgdc-10ncbjr. the exhaust blower Goodman piston size chart r22Checking the charge on a heat pump in the winter R410a charging chartRheem hvac ac b702 9ce1 4acf.4 To 5 Ton TXV Kit - R-410A Refrigerant. ( 5 Reviews) Model: Blueridge BGH4TXV03. $ 109.99. Or as low as. Buy in monthly payments with Affirm on orders over $50. Learn more. You save: 30%. Compare to: $157.92.Piston size-non tXV use Tonnage R22 (F) R410A (G) Orifice Sz PART # Orifice Sz PART # 1T 0.041 3962 N/A N/A 1.5T 0.055 3999 0.049 4006 2T 0.059 4000 0.055 3999 4 ton 410a piston size, Available for environmentally sound R-410A systems; Factory installed piston metering device with Teflon ring on 1.5 - 4 ton sizes, TXV on 5 ton size; Sweat connections; Primary and secondary drain fittings; Multiple electrical entry locations; Time delay relay (TDR) Field installed heater packages from 5 kW - 30 kW available separately, The Goodman® GSZ13 heat pump uses the environmentally friendly refrigerant R-410A and features operating sound levels that are among the best in the heating and air conditioning industry. R-410A is chlorine-free to help prevent damage to the ozone layer. With its 13 SEER rating, the GSZ13 will help reduce energy consumption throughout the life ... , Mars cares a lot about "fun." Maybe a little too much. Mars—maker of M&Ms, Snickers, Twix, and many more sugary delights—is all about fun. Mars was the first company to have the fu..., Buy Goodman B1789857 2 Ton Orifice Kit for R-410A, 14 SEER Air Conditioner. Goodman technical support information, product brochures and more. ... This orifice (also referred to as a piston) is installed in an evaporator coil when the coil has a different tonnage rating than the condenser tonnage rating. Installation takes about 5 minutes, …, Goodman 4 - 5 Ton, Cased Evaporator Coil (W 24-1/2 x D 21 x H 30) - Cased TXV Included. SKU: CAPT4961D4 Goodman, The massive iceberg that calved off the Larsen-C shelf last July exposed a previously unexplored region of seafloor. When A-68, a trillion-ton iceberg the size of Delaware (or ten ..., Carrier tech support called and back and said, 56 or 57 - depending on what indoor coil it is. Product Data manual stated - #57 indoor piston and #46 outdoor piston (heating). If you want the manuals, let me know and I will email them to you. Instead of learning the tricks of the trade, learn the trade., May 13, 2014 · I just had a new condenser and evaporator installed, a Goodman model GSX130481BC 4 ton condenser and 4-5 ton Goodman model CHPF4860D6DB coil using R410A. The day after install, the system produced about a 14 degree F drop between the air intake and outlet vents. , The duration of warranty coverage in Texas and Florida differs in some cases. At Goodman, we believe in American dependability. Units are designed, engineered and assembled in the U.S.A. Learn more about Goodman brand energy-efficient ARUE Series Air Handler - HVAC designed, engineered and assembled in the USA!, 3 Ton Piston Size 73 R-22/R-410A . California residents: see Proposition 65 Warning. Features and Specification Weight: 2: Brand: Advanced Distributor Products: Composition: Copper: Connection Size: 3/8" Connection Type: Solder: Cubic Measurement: 0.1458: Height: 6: Inlet Connection Size: 3/8" Length: 7: Maximum Working Pressure:, Rheem Air Handler. FORM NO. H11-545 REV. 1. RHBL- Series. X-13 (ECM) Motor Efficiencies up to 16 SEER. RHAL- Series. PSC Motor Efficiencies up to 14.5 SEER. † Front or Bottom Return † Flow Check Piston for cooling or heat pump operation † Wall-hanging brackets † Built in Filter Rack † AHRI Certified † UL Certified † Molex Plug ..., According to my chart the GSZ14048 takes a .80 piston. Also Goodman does not ship the piston with the 14 SEER condensers. I guess they wanted to save a buck per unit since most have the option for TXV too. You definitely can not count on the correct piston being shipped in the AH or coil either., None of the systems I retrofitted employed pistons after converting to 410A. The largest system I did was 5 ton. Some utilized pistons with 22 but I put in TXVs for 410A. Some others utilized TXVs with 22 and I just changed the TXV. These were all split system but I have seen some 7.5 ton 410A RTUs with pistons. New build though, not retrofitted., Residential Fan Coil; with standard features:ENVIRONMENTALLY SOUND R-410A SYSTEMSFactory installed piston metering device with Teflon ringHigh efficiency ECM, 5-speed motorCopper tube/aluminum fin coil on standard modelsAvailable with industry exclusive t , MFH COIL AC PISTON .093 4-5T STD-HI EFF 13-15 SEER. ... PISTON .093 4-5T. -Product Detail. CMH48/60PM2M. MFH ... 410A Nom. Capacity (Tons) 4-5 Fits Furnace Width ( ..., Factory R410A TXV R-22 TXV = Mainline Kit # NAEA20401TX, NAEA20501TX, NAEA20601TX, and NAEA20701TX. Consult the chart below for proper size application. – comprehensive chart on pages 2 - 4 – Mainline kit FAST part Label Convert from R-410A PISTON to R-22 TXV Model Size 18 24 30 36 42 48 60 , Commercial 27.5 to 50 ton 60 hz, 22.9 to 41.7 ton 50 hz cv or vav rooftop air conditioners with reliatel controls, r-410a refrigerant (152 pages) Air Conditioner Trane Voyager YS 150–300 Installation, Operation And Maintenance Manual. ... See Table 1 for factory installed piston size. Some system combinations will require a different sized ..., Oxbox J4MXCC009AC6HCA - 4 - 5 Ton Multi-Position Cased Evaporator Coil (21" W x 21" D x 30" H)- Product Features: Oxbox indoor coils can be adapted to 13, 14 and 16 SEER models 1.5 – 5 ton models available All-aluminum coil design Multi-positional installation — upflow, downflow, horizontal left, horizontal right Foil-faced thermal ..., piston kit chart 4 ppkcg-4001j february 2015 (*) signifies unit revision. (1) correct piston is supplied with the outdoor unit. (2) correct piston is supplied in the highest sales volume tested combination indoor unit. for all other indoor combinations, piston must be purchased from distributor. (3) txv must be purchased separately. , Lennox Elite CH35, CH35-51C-2F, 4 Ton, Piston (R410A), Cased Aluminum Horizontal Evaporator Coil. Cat # : 10C38 ... 4 Ton . Metering Device. Piston (R410A) Product ..., Standard size coils (1.5 to 5 tons) HP-A/C TXV R410A (non-bleed) Large Tonnage Coils . HP-A/C TXV R-22 (non-bleed) Large Tonnage Coils . TXV Large tonnage coils (Discontinued) ... standard R-22 and R-410A pistons listed above (100 pistons total) in a plastic case 176799800. 1; All piston models. Miscellaneous. Part Number. Qty. Used …, This manual is also suitable for: View and Download Daikin R-410A technical data manual online. Outdoor units. R-410A air conditioner pdf manual download. Also for: Rxs-g2v1b., Flowcheck Pistons. Showing 1 - 12 (of 49) results. Part # 61-22119-68., Refrigeration Type. R-410A. Cooling Efficiency (EER) UP TO 10.85. Phase. 3. Capacity Range (BTU) 37200-83000. Voltage@Hz., Piston r410a Solved 9.4 kg of r-134a fill a 0.7-m3 weighted Answer solved problem. ... 2 1/2 Ton R410A | Gemaire. Check Details. Piston Size Chart R22 Goodman - Best ..., Qty. $239.00. Diversitech 3/8" Sight Glass Sweat for Air Conditioner Condenser View Item. Add To Cart. Qty. $32.95. The Goodman GSXN3N2410 is a 2 ton cooling-only condenser unit. Providing a 13.4 SEER2 efficiency with a single stage, reciprocating compressor, the GSXN3N2410 is an inexpensive condenser to cool your home when paired with an AC coil., The Goodman® GSZ13 heat pump uses the environmentally friendly refrigerant R-410A and features operating sound levels that are among the best in the heating and air conditioning industry. R-410A is chlorine-free to help prevent damage to the ozone layer. With its 13 SEER rating, the GSZ13 will help reduce energy consumption throughout the life ... , I have a 1991 Rheem 2.5 ton A/C and coil. Last summer, it lost all 4 lbs of R-22. I've got several proposals for replacing it with a new compressor and coil using R-410a. All the proposals specify reuse of the existing 3/4" and 3/8" lineset. The suction line has a severe bend, almost to the point of being crimped, just before it enters the outdoor unit …, Rheem Air Handler. FORM NO. H11-545 REV. 1. RHBL- Series. X-13 (ECM) Motor Efficiencies up to 16 SEER. RHAL- Series. PSC Motor Efficiencies up to 14.5 SEER. † Front or Bottom Return † Flow Check Piston for cooling or heat pump operation † Wall-hanging brackets † Built in Filter Rack † AHRI Certified † UL Certified † Molex Plug ..., For R22 2.0 ton or R410A 2.5 ton units. .059 opening. Email a Friend. 888-341-7330., The YORK® LX Series YC2D 13.4 SEER2 Single-stage Air Conditioner provides reliable operation that meets your needs and fits your budget. With robust compressor technology that's been proven in our extreme, accelerated-wear test facility, its compact cabinet fits advanced performance in less space. A direct-drive fan design minimizes vibration ..., The Goodman® GSZ13 heat pump uses the environmentally friendly refrigerant R-410A and features operating sound levels that are among the best in the heating and air conditioning industry. R-410A is chlorine-free to help prevent damage to the ozone layer. With its 13 SEER rating, the GSZ13 will help reduce energy consumption throughout the life ..., R-410A 2 Ton; R-22 1.5 Ton; Piston Size 53; Specifications Product Name: Piston #53 2T R410A Brand Name: ADP Item # 100000036 Weight: 1 lbs Length: 12 in Width: